Jusha M350G 3MP Monochrome Diagnostic Display

  • High grayscale
  • Ins-guard real-time DICOM automatic calibration system
  • Full-screen brightness equalization calibration SLE
  • FocusView /Spotlight
  • X-ray Film View (XFV)
  • Ambient Brightness Adaption
  • SmarTouch technology
  • Presence Sensor/ Eco-guardian
  • Calibration by front sensor
  • JUSHA Qualitas QA Compatible
MASTER DISTRIBUTOR
24X7 SUPPORT
COMPETITIVE PRICING
SAME DAY SHIPPING
VALUABLE CONSULTATION

Jusha M350G 3MP 21.3″ Monochrome Diagnostic Display

JUSHA M350G professional display adopts industry-leading LED technology with advantages of high brightness, high grayscale level, uniform brightness, energy saving and environmental protection, and long service life. In addition, it features high resolution, high brightness and 16bit grayscale (65536 level), built-in DICOM standard LUT. It can be used in demanding clinical diagnostic applications, such as: PACS, CR, DR, MR, CT and other diagnostic equipment.

High grayscale
This Jusha M350G product features a 16bit LUT that can display 65536 level grayscale with smoother image transition. It ensures that 16-bit grayscale image from high-end imaging equipment can be presented completely in front of a doctor. In addition, it is also helpful for diagnosing early-stage lesions that have extremely small grayscale difference from normal tissue.

Ins-guard real-time DICOM automatic calibration system
JUSHA Ins-guard system is a DICOM real-time automatic calibration system. If monitors the brightness of the center point of the screen in real time through a built-in brightness sensor, and feeds back to the correction system to automatically calibrate the brightness of the LCD panel to ensure compliance with DICOM standards. The center point measures and controls the brightness, making it more in line with the screen brightness requirements in the actual viewing area.

This product adopts dynamic LUT technology. Compared with the traditional LUT, DICOM correction is no longer limited to the brightness curve previously set in the LUT. The dynamic LUT technology can be used to perform DICOM correction of the display’s real-time brightness and contrast to ensure that the entire brightness range of the medical display complies with DICOM standards.

Full-screen brightness equalization calibration SLE
JUSHA M350G full-screen brightness equalization system SLE measures and calibrates the brightness of each pixel of the monitor to ensure that the brightness uniformity meets the medical display requirements.

FocusView /Spotlight
When the lesion focusing function is on, the full-screen brightness is reduced. At the same time, by using the software to capture the coordinates of the mouse, a circular area or a rectangular area with the the mouse coordinates as the center and radius R is highlighted to the highest corrected brightness like a stage spotlight to highlight lesions for easy diagnosis.

X-ray Film View (XFV)
The XFV can increase the brightness of the monitor to peak value, which can replace the traditional Lightbox for film reading and increase work efficiency.

Ambient Brightness Adaption
JUSHA ambient light detection system can detect the ambient light, further adjust the display effect to make it fitter for eye-viewing and display images under various lighting environments.

SmarTouch technology
JUSHA developed SmarTouch technology. By clicking the SmarTouch button, the brightness of the display can be instantaneously changed. At the same time, the BIA quickly stabilizes the brightness based on the brightness enhancement technology while protecting the doctor’s eyesight during accurate diagnosis.

Presence Sensor/ Eco-guardian
JUSHA Eco-guardian function detects the presence of people in front of the display using remote sensing. In the set time, it can automatically enter the standby state, so as to achieve better energy-saving and prolong the service life of the monitor. In addition, this function can also identify users and non-living objects such as chairs, making the operation easier and more intelligent.

Calibration by front sensor
The Jusha M350G front sensor can detect the brightness of the light emitted by the display panel, work with the backlight sensor to detect the brightness and ensure that the brightness of the LCD panel meets the DICOM standard.

JUSHA Quality QA Compatible
Users can check and calibrate the monitor status by themselves, removing the side effects from panel’s aging, which prolongs the lifespan of the monitor and achieving more accurate image.

Support

Model: M350G

Specifications

Model M350G
Type IPS
Backlight LED
Diagonal size 21.3″
Display area 433.15(H)×324.86(V)mm
Resolution 2048×1536
Aspect ratio 4:3
Pixel pitch 0.2115mm×0.2115mm
Color depth 10 bit
Lut depth 65536
Viewing angles 178°
Maximum brightness typical 2000 cd/m²
Maximum calibrated brightness 1000 cd/m²
Default brightness 500 cd/m²
Minimum brightness 200 cd/m²
Presets DICOM/GAMMA2.2/GAMM2.4/ CT/MRI-JS /DSA/DSI/BYPASS
Uniformity calibration Yes
Contrast ratio 1500:1
Response time 14 ms
Quality QA Yes
Features SmarTouch, XFV、PI、ABA、ALC、Real-time DICOM calibration
Video input DP x 1, DVI x 1
Video output DP x 1
Usb ports Upstream USB-B 2.0 x 1 Downstream USB-A 2.0 x 2
Power input 24V DC-3.75A
Typical power 30 W
Maximum power 55 W
Power saving < 0.5 W
Backlight stabilizer Yes
Front sensor Yes
Ambient light sensor No
Other sensors Human,Temperature
Protective glass No
Housing color Silver
Dimensions with stand 382mm*635mm*238mm
Dimensions without stand 382mm*490mm*77mm
Net weight with stand 10±0.5kg
Net weight without stand 6.3±0.5kg
Vesa 100×100 mm 1
Certifications CE, FDA , CCC, Inmetro, EAC, Energy saving

Free Barco White Paper

Receive special pricing from the top medical display companies along with white papers and software updates:

Sign up to Newsletter & Follow us