NEW! JVC 2MP 21.3 Clinical Review Display – CL-R211

JVC CL-R211 (CLR211) 2MP 21.3” Clinical Review Display is an optimal solution where doctors need to view both grayscale and color images, and effectively covers multiple applications like PACS, CAD, PET and nuclear medicine.

Dynamic Gamma — One Pixel Based Contrast and Brightness, Gamma.

Call for Best Price!

MASTER DISTRIBUTOR
24X7 SUPPORT
COMPETITIVE PRICING
SAME DAY SHIPPING
VALUABLE CONSULTATION

JVC CL-R211 (CLR211) 2MP 21.3 Clinical Review Display

With the JVC CL-R211 (CLR211) Color images are automatically recognized to provide optimized contrast, brightness, and gamma. No user intervention is required.

Auto Text Mode — Auto-Brightness Blinding Mode for Text Area

Automatic brightness control for text data to reduce eye strain for patient lists and reporting applications.

LED Backlight for Image Stability and Energy Saving

Compared to the conventional CCFL backlight models, JVC CL-R211 (CLR211) with LED backlight system saves energy and will hold brightness much longer. Additionally, a mercury-free LED backlight contributes to reduce environmental impacts.

Built-in Sensor

With two built-in sensors for luminance stabilization and ambient light measurement, JVC CL-R211 consistently delivers unmatched image quality.

Ambient light sensor

An ambient light sensor is built-in so that calibration appropriate for the effects of ambient luminance is carried out.

Luminance sensor

The luminance sensor attached in front of the screen constantly monitors and accurately stabilizes luminance on the screen surface by sending feedback to the control circuit.

Remote Calibration

DICOM conformance check and calibration can be remotely performed. These remote management features will minimize the burden of system administrators.

Optional PM Medivisor software is required.

DICOM Conformance Check

User-friendly OSD functions include the DICOM conformance check function.

Display Quality Control

The Medivisor Series software is a user-friendly tool to effectively manage JVCKENWOOD’s displays. Calibration software Medivisor Nx, quality assurance software QA Medivisor and performance monitoring software PM Medivisor interact closely with each other to help system administrators easily manage all JVCKENWOOD’s displays in the network.

DisplayPort

The JVC CL-R211 (CLR211) implemented Display Port with 10-bit depth color in addition to conventional DVI input and achieved 1billion 64 million simultaneous colors with 10-bit input.

Uniformity Equalizer

The luminance uniformity correction system will produce stable images across the screen.

User-selectable Display Configurations

Luminance/gamma settings are selectable from three preset levels according to the needs. The user-selectable configuration enables stress-free operations without specialized settings.

OSD Information Display

With a push of a button, the display’s current status can be checked such as the display model, total operating time, actual measurement of luminance, and calibration settings.

Display Status Indicator

The current display operating status can easily be checked by the front LED indicator.

Worldwide Medical Safety Standards

JVC CL-R211 meets worldwide medical safety standards.

About JVC-Kenwood

JVC-Kenwood is a leading worldwide manufacturer of medical image displays and touch panel displays. Its high-end, high-cost-performance medical image displays and touch panels are backed by its unique technology and know-how through decades of solid experience in the industry since 1972.

JVC-Kenwood has supplied computer displays for factories, broadcast stations, workstations, and other applications, and has earned high marks for its product reliability under harsh conditions and post-installation support, not to mention specialized technologies required for respective fields.

JVC-Kenwood continues to provide high-performance displays for specialized fields by developing leading-edge technologies while providing consistently optimal customer service.

SPECIFICATION

Model Name
CL-R211
LCD Panel
Technology
21.3″ color TFT IPS technology
Display Area
324 mm x 432 mm
Pixel Pitch
0.270 mm x 0.270 mm
Contrast Ratio
1800:1(typ.)
Maximum
Luminance
500cd/㎡(typ.)
280 cd/㎡ ・ 250 cd/㎡ (calibrated)
Viewing Angle
178° vertical and horizontal
Visual Performance
Native Resolution
1200×1600
Display Colors
16.77 million colors from a palette of 68 billion colors
1.07 billion colors with DisplayPort and 10-bit viewer
Interface
Input Signal
DVI-D(DVI 1.0 compliant)
DisplayPort(DisplayPort 1.2a compliant)
Plug and Play
DDC2B compliant
Input Power Supply
Input Power Supply
100V-240V  50/60Hz
Maximum Power Consumption
45W(typ.)
Features
Calibration Control
Luminance,Gamma,Color temperature
Capable of storing 3 sets of LUT
(Optional Calibration Kit is required)
OSD Information Display
Model name, Serial No., Total operating time,
Calibration settings (Operating time since last calibration, Luminance, Gamma),
Current luminance, Color temperature and Ambient light, DICOM conformance
USB Hub
USB Rev. 2.0 compliant, Self-powered
USB upstream connector (x1),
USB downstream connector (x2)
Other Features
Uniformity Equalizer, Hardware pivot, LED indicator, DisplayPort Daisy Chains,
Advanced power management, Human Presence Sensor, Dynamic Gamma,
Auto Text Mode, Luminance stabilization, Multiple LUT, Self DICOM check, Self-calibration
Approvals
ANSI/AAMI ES60601-1(2005)+A1(2012), CAN/CSA-C22.2 No.60601-1(2014), CE(EN60601-1, EN60601-1-2),
RCM, FCC Part15 subpart B Class B, ICES-003-B, VCCI-B, FDA510(k), J-Moss, RoHS, EAC
Physical Characteristics
Dimensions
(W × H × D)
Landscape: 493 mm × 451.3 / 546.3 mm × 196.5 mm
Portrait: 361.5 mm × 517 / 612 mm × 196.5 mm
Weight
8.9 kg
Tilt Stand
Tilt, Swivel, Portrait / Landscape
Mount
VESA standard (100 mm x 100 mm)
Security Slot
Anti-theft security slot
Accessories
Power cord, DVI cable, DisplayPort cable, USB cable, Operation manual,
Installation manual, Software(QA Medivisor Agent LE)

DIMENSIONS

OPTIONS

CL-R211

Graphics cards
Graphics Card
CAL-016 (Calibration Kit)
Calibration and QA testing software and Calibration sensor
CAL-016 (Calibration Kit)
PM Medivisor (PM-001A)
Display performance monitoring software
PM Medivisor (PM-001A)
QA Medivisor
Acceptance and constancy testing software
QA Medivisor
Medivisor Nx
Calibration software
Medivisor Nx

Free Barco White Paper

Receive special pricing from the top medical display companies along with white papers and software updates:

Sign up to Newsletter & Follow us